4.16 Enter/change password
When a password has been set, only the main menus can be accessed until the correct password has been entered.
• MASTER –> EPM
• DISPLAY CONTRAST
• MISCELLANEOUS (without the submenu PASSWORD).
Press The display shows... Explanation
1.
MENU
MISCELLANEOUS
Press the key until the menu appears in the display.
2.
ENTER
S
/W VERSION X.XX
Takes you to the submenu. The cursor is blinking in
the display on the left.
3.
P
ASSWORD: 0000
Displays the set password for the access protection
(Factory setting: 0000).
When the password is set to 0000, the access
protection is deactivated.
4.
ENTER
PASSWORD: 000
0
The cursor is blinking in the display on the right.
5.
PASSWORD: XXX
X
Enter a password. Any value between 0000 and
9999.
Use the
buttons to select a value. To scroll
quickly to a value, keep the key pressed. The scroll
rate increases as you hold the button.
6.
ENTER
P
ASSWORD: XXXX
The cursor is blinking in the display on the left.
The new password has been stored.
7.
MENU
MISCELLANEOUS
Returns to the main menu.