Technical data
Rated data
4
l
45
EDKRBG018R DE/EN/FR/ES/IT 7.0
4.2 Rated data
Electrical data
R
B
P
d
Q
B
U
max
[W] [W] [kWs] [V
DC
]
ERBG023D05K6 2.3 5600 840
1000
ERBG028D04K1 2.8 4100 615
ERBG035D03K3 3.5 3300 495
ERBG043D03K0 4.3 3000 450
ERBG005R02K6 5.0 2600 390
ERBG075D01K9 7.5
1900 285
ERBG012R01K9
12.0
ERBG012R05K2
5200 780
ERBG015R03K3
15.0
3300 495
ERBG015R06K2 6200 930
ERBG015R10K0 10000 1500
ERBG018R04K3 18.0 4300 645
R
B
Resistance
P
d
Permanent power
Q
B
Heat quantity
U
max
Max. operating voltage
Temperatures
T
nom
T
TK
T
max
[°C]
Inside 390 530 690
At the housing 200 240 300
On the clearance
edge
*)
120 160 200
T
nom
Maximum temperature for rated data
T
TK
Temperature at which the thermal contact is activated
T
max
Maximum temperature in the case of improper use
*) Measured for air as the ambient medium (small coefficient of thermal
conductivity); if materials which heat up are located at the clearance edge
(greater coefficient of thermal conductivity), the temperature continues to
rise.