Questions and Answers

  • A
    Aaron SmithAug 23, 2025
    What to do if Lenze DC Drives show a short-circuit or overload?
    • J
      Jerry SheltonAug 23, 2025
      If the Lenze DC Drives indicate a short-circuit or overload, the cause may be a short-circuit. You should find the reason for the short-circuit and check the motor cable. It can also be caused by excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current. If the acceleration time is too short, increase the acceleration time and check the controller selection. Also, check wiring if the motor cable is defective and check the motor for internal faults. If there is frequent and long overload, check the controller selection.
  • B
    Brent LaneSep 1, 2025
    How to fix communication error on Lenze ESMD302L4TXA?
    • S
      staceymurphySep 1, 2025
      If the Lenze Inverter reports a communication error, it could be due to the serial timer timing out. In this case, check the serial link connections.
  • P
    pricetaraSep 1, 2025
    What causes undervoltage on DC bus in Lenze Inverter?
    • S
      Shawn PerezSep 1, 2025
      If the Lenze Inverter shows 'Undervoltage on DC bus', the mains voltage might be too low. Check the mains voltage to ensure it is within the required range.
  • R
    Ryan GuzmanSep 2, 2025
    How to resolve Lenze ESMD302L4TXA stop with inhibited outputs?
    • C
      Chase MckaySep 2, 2025
      If the Lenze Inverter stops and the outputs U, V, W are inhibited, it is because there is a LOW signal at terminal 28. To solve this, set terminal 28 to HIGH.
  • S
    Stephanie BallSep 3, 2025
    How to troubleshoot Dynamic braking fault on Lenze Inverter?
    • A
      Angela GutierrezSep 3, 2025
      If the Lenze Inverter is showing a Dynamic braking fault, it indicates that the dynamic braking resistors are overheating. To resolve this, increase the deceleration time.
  • B
    Bobby Hill MDSep 4, 2025
    Why is Lenze ESMD302L4TXA Inverter output frequency 0 Hz?
    • C
      Christine SmithSep 4, 2025
      If the Lenze Inverter's output frequency is 0 Hz and the outputs U, V, W are inhibited, it could be due to: * Setpoint = 0 Hz (C31 = 0): In this case, you need to perform a setpoint selection. * Quick stop activated through digital input or serial link: Deactivate the Quick stop.
  • M
    Maurice McmahonSep 4, 2025
    Why are Lenze ESMD302L4TXA Inverter buttons not working?
    • H
      Heather BrooksSep 4, 2025
      If the Lenze Inverter indicates that the remote keypad is active, the buttons on the front of the controller are disabled. This is normal operation when the remote keypad is in use.
  • T
    Todd CruzSep 5, 2025
    What to do for Controller overtemperature on Lenze ESMD302L4TXA Inverter?
    • C
      Caitlin SimpsonSep 5, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • R
    Rachel SmithSep 6, 2025
    What does current limit reached mean on Lenze ESMD302L4TXA?
    • S
      Steven DaySep 6, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • K
    Kendra FoxSep 7, 2025
    How to fix No access to code on Lenze Inverter?
    • P
      perezblakeSep 7, 2025
      If the Lenze Inverter displays 'No access to code', it means that changes can only be made when the controller is in OFF or 1nh. To proceed, set terminal 28 to LOW or inhibit by serial link.

Summary

Safety Information

About these instructions

General introduction to the documentation and safety aspects.

General Safety and Operation

Covers general precautions, electrical hazards, application, installation, and operation safety.

Hazard Symbols and UL Notes

Explains safety pictograms and provides specific notes for UL systems.

Technical Data

Standards and Application Conditions

Specifies conformity, approvals, and environmental conditions for operation.

Ratings and Specifications

Details power, voltage, current, and frequency ratings for various models.

Installation

Mechanical Installation and Dimensions

Covers dimensions, mounting, and environmental considerations for installation.

Electrical Installation and EMC

Guidelines for electrical installation, wiring, fuses, and EMC compliance.

Connection Diagram and Storage

Illustrates connection points and provides instructions for long-term storage.

Control Terminals Overview

Describes the function and configuration of various control terminals.

Commissioning

Parameter Setting Process

Overview of setting parameters via keypad and EPM.

Electronic Programming Module (EPM)

Functionality and use of the EPM for parameter storage.

Key Parameter Configuration Groups

Covers essential parameters for settings, inputs, outputs, and motor control.

Advanced Settings and Fault Management

Configuration for serial communication, fault handling, and advanced settings.

Troubleshooting & Fault Elimination

Status and Cause Analysis

Lists operational statuses, causes of faults, and basic remedies.

Error Codes and Remedies

Detailed explanations of error codes, their causes, and corrective actions.

Lenze ESMD302L4TXA Specifications

General IconGeneral
Input Voltage380-480VAC
Input Frequency47-63 Hz
Output Frequency0-500 Hz
Rated Power3.0 kW
Protection ClassIP20
TypeInverter
Output Voltage0-Input Voltage
Output Current7 A
Control MethodV/f control
Cooling MethodAir cooling
Communication InterfaceRS485
Operating Temperature-10°C to +50°C