Questions and Answers

  • J
    Johnny McfarlandAug 25, 2025
    What to do if Lenze DC Drives show a short-circuit or overload?
    • J
      Jonathan ShahAug 25, 2025
      If the Lenze DC Drives indicate a short-circuit or overload, the cause may be a short-circuit. You should find the reason for the short-circuit and check the motor cable. It can also be caused by excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current. If the acceleration time is too short, increase the acceleration time and check the controller selection. Also, check wiring if the motor cable is defective and check the motor for internal faults. If there is frequent and long overload, check the controller selection.
  • M
    Mrs. Amanda FreemanSep 1, 2025
    How to fix communication error on Lenze ESMD371L4TXA?
    • C
      Christopher LindseySep 1, 2025
      If the Lenze Inverter reports a communication error, it could be due to the serial timer timing out. In this case, check the serial link connections.
  • O
    ohessSep 1, 2025
    What causes undervoltage on DC bus in Lenze ESMD371L4TXA Inverter?
    • M
      Michael ShortSep 2, 2025
      If the Lenze Inverter shows 'Undervoltage on DC bus', the mains voltage might be too low. Check the mains voltage to ensure it is within the required range.
  • D
    David BeckSep 2, 2025
    How to resolve Lenze Inverter stop with inhibited outputs?
    • W
      williamsjerrySep 2, 2025
      If the Lenze Inverter stops and the outputs U, V, W are inhibited, it is because there is a LOW signal at terminal 28. To solve this, set terminal 28 to HIGH.
  • K
    Kylie JamesSep 3, 2025
    How to troubleshoot Dynamic braking fault on Lenze Inverter?
    • N
      Nicholas ClarkeSep 3, 2025
      If the Lenze Inverter is showing a Dynamic braking fault, it indicates that the dynamic braking resistors are overheating. To resolve this, increase the deceleration time.
  • R
    richard38Sep 4, 2025
    Why is Lenze ESMD371L4TXA Inverter output frequency 0 Hz?
    • S
      Sandra CameronSep 4, 2025
      If the Lenze Inverter's output frequency is 0 Hz and the outputs U, V, W are inhibited, it could be due to: * Setpoint = 0 Hz (C31 = 0): In this case, you need to perform a setpoint selection. * Quick stop activated through digital input or serial link: Deactivate the Quick stop.
  • J
    Joanne RobinsonSep 4, 2025
    Why are Lenze Inverter buttons not working?
    • C
      Christopher DelacruzSep 4, 2025
      If the Lenze Inverter indicates that the remote keypad is active, the buttons on the front of the controller are disabled. This is normal operation when the remote keypad is in use.
  • N
    Nicole ZamoraSep 5, 2025
    What to do for Controller overtemperature on Lenze Inverter?
    • B
      Brad WrightSep 5, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • M
    Melissa FerrellSep 6, 2025
    What does current limit reached mean on Lenze Inverter?
    • T
      Todd MillerSep 6, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • J
    Julia FordSep 7, 2025
    How to fix No access to code on Lenze ESMD371L4TXA Inverter?
    • F
      fjordanSep 7, 2025
      If the Lenze Inverter displays 'No access to code', it means that changes can only be made when the controller is in OFF or 1nh. To proceed, set terminal 28 to LOW or inhibit by serial link.

Summary

Safety Information

General Safety Precautions

Essential safety measures for handling and operating the inverter.

Application Guidelines

Correct usage and directives for drive controllers in machinery.

Installation Safety

Precautions during transport, handling, and physical installation.

Electrical Connection Safety

Guidelines for safe electrical wiring and connections.

Operational Safety

Danger Warnings

Critical warnings about electrical hazards and component behavior.

Pictographs and Symbols

Danger Symbols

Pictograms indicating hazardous electrical voltage and personal danger.

Warning and Stop Symbols

Symbols for equipment damage warnings and operational stops.

UL System Safety Notes

UL Specific Warnings

Special warnings applicable to UL approved systems.

Capacitor Discharge Warning

Critical warning about residual charge in capacitors after power off.

Protective Device Opening Warning

Warning regarding potential fire or shock from protective device operation.

Inverter Ratings

Output Current Performance

Rated and maximum output currents for various conditions.

Installation Procedures

Mechanical Installation

Guidelines for physical mounting and placement.

Electrical Installation

EMC Compliance Requirements

Steps to ensure electromagnetic compatibility during installation.

Fuses and Cable Sizing

Recommendations for protective devices and wire gauges.

Connection Diagrams and Warnings

Electrical Connection Diagram

Visual guide for wiring power and control connections.

Critical Storage Warning

Warning about capacitor damage and reforming procedures.

Critical Electrical Safety

Safety warnings regarding electrical shock and output terminal connections.

Control Terminal Functions

Terminal Functionality

Detailed description of each control terminal's purpose.

Commissioning Steps

Parameter Setting Guide

Procedures for navigating and changing inverter parameters.

Parameter Menu Reference

Parameter Code and Name

List of parameter codes and their descriptive names.

Parameter Settings and Options

Available selections and Lenze's recommended settings.

Parameter Important Notes

Critical information and usage advice for parameters.

Parameter Settings: Frequency and Timing

Advanced Commissioning Parameters

Specific Parameter Configurations

Communication and Status Parameters

Further Commissioning Parameters

Troubleshooting and Fault Elimination

Error Codes and Causes

Listing of error codes and their primary causes.

Specific Error Code Resolutions

Short-Circuit and Earth Faults

Troubleshooting steps for short-circuit and earth fault errors.

Overload and Overvoltage Errors

Remedies for motor overload and DC bus overvoltage.

Lenze ESMD371L4TXA Specifications

General IconGeneral
Input Frequency50/60 Hz
Rated Power3.7 kW
Output Power3.7 kW
Protection ClassIP20
TypeInverter
Input Voltage380-480 V
Output Voltage0-480 V
CoolingAir cooling
Control MethodV/f control
Cooling MethodForced air cooling