Lenze SMVector 13554876 EDBSV01 EN v21.0 11
Technical Data
600VAC Models
600V Three Phase (3/PE) (425...660V); 48...62Hz
Type
Power Mains Current Output Current Heat Loss (Watts)
Hp kW A
Cont (I
n
)
A
Max I
%
N1/IP31 N4X/IP65
No filter
N4X/IP65
W/ filter
ESV751--6T-- 1 0.75 2 1.7 200 37 31
ESV152--6T-- 2 1.5 3.2 2.7 200 51 43
ESV222--6T-- 3 2.2 4.4 3.9 200 68 57
ESV402--6T-- 5 4 6.8 6.1 200 101 67
ESV552--6T-- 7.5 5.5 10.2 9 200 148 116
ESV752--6T-- 10 7.5 12.4 11 200 172 152
ESV113--6T-- 15 11 19.7 17 180 380 356
ESV153--6T-- 20 15 25 22 180 463 431
ESV183--6T-- 25 18.5 31 27 180 560 519
ESV223--6T-- 30 22 36 32 180 640 592
ESV303--6T-- 40 30 47 41 180 930
ESV373--6T-- 50 37.5 59 52 180 1163
ESV453--6T-- 60 45 71 62 180 1395
NOTES:
Output Current: The Output Current Maximum (%) is a percentage of the Output Current Continuous Amps (In) rating
and is adjustable in parameter P171.
STOP!
For installations above 1000m a.m.s.l., derate I
n
by 5% per 1000m, do not
exceed 4000m a.m.s.l.
Operation above 40°C, derate I
n
by 2.5% per °C, do not exceed 55°C.
Output Current (In) derating for Carrier Frequency (P166) for NEMA 1 (IP31) Models:
- If P166=2 (8 kHz), derate I
n
to 92% of drive rating
- If P166=3 (10 kHz), derate I
n
to 84% of drive rating
Output Current (In) derating for Carrier Frequency (P166) for NEMA 4X (IP65) Models:
- If P166=1 (6 kHz), derate I
n
to 92% of drive rating
- If P166=2 (8 kHz), derate I
n
to 84% of drive rating
- If P166=3 (10 kHz), derate I
n
to 76% of drive rating