Configuration
821XKlimaBA0399 7-13
Code IMPORTANTPossible settingsNameCode IMPORTANT
InfoSelectionLenze
Name
C427* Offset adjustment
frequency input
E1
0.0 -12.5 {0.1 %} 12.5
C500* Display factor
2000 1 {1} 25000
numerator
C501* Display factor for
10 1 {1} 25000
denominator
C597*
¤
Activation of
motor-phase
failure detection
822X/824X -0- -0- Inactive
-1- TRIP
-2- Warning
C599*
Current limit
value
motor-phase
failure detection
822X/824X 5 1{1%} 50
C625* Frequency 1 480.00 0.00 {0.02 Hz} 480.00
C626* Frequency 2 480.00 0.00 {0.02 Hz} 480.00
C627* Frequency 3 480.00 0.00 {0.02 Hz} 480.00
C628* Bandwidth of
frequencies
0.00 0.00 {0.01 %} 100.00
C988* DC-bus voltage
threshold for
DC-bus voltage
control
0 0 {1 %} 200
-
C988 = 0%
-No
parameter
set
changeover
via DC-bus
voltage
-
C988 = 1 ...
200%
- Parameter
set
changeover
via DC-bus
voltage
active
Parameter set
changeover via
terminal or
LECOM is not
possible when