Technical data
Electrical data
3
55
EDK94AMH24 DE/EN/FR/ES/IT 1.0
Output data
Voltage Frequency Current [A] Current [A]
Number
of phases
Type [V] [Hz] c max. +45° C c max. +55° C
E94AMxE0024 0 - 230/400/500 0 - 480 1.5/1.5/1.3 1.1/1.1/1.0 3
E94AMxE0034 0 - 230/400/500 0 - 480 2.5/2.5/2.2 1.9/1.9/1.7 3
E94AMxE0044 0 - 230/400/500 0 - 480 4/4/3.5 3/3/2.6 3
E94AMxE0074 0 - 230/400/500 0 - 480 7/7/6.1 5.3/5.3/4.6 3
E94AMxE0094 0 - 230/400/500 0 - 480 9.3/9.3/8.2 7.0/7.0/6.2 3
E94AMxE0134 0 - 230/400/500 0 - 480 13/13/11.4 9.8/9.8/8.6 3
E94AMxE0174 0 - 230/400/500 0 - 480 16.5/16.5/14.4 12.4/12.4/10.8 3
E94AMxE0244 0 - 230/400/500 0 - 480 23.5/23.5/20.6 17.6/17.6/15.5 3
c Ambient temperature in the control cabinet
Power loss P
V
[W]
Type Total (when operating with I
aNx
) Constant (when controller is inhibited)
E94AMxE0024 100
40
E94AMxE0034 120
E94AMxE0044 150
E94AMxE0074 190
E94AMxE0094 230
E94AMxE0134 280
E94AMxE0174 320
E94AMxE0244 420
Assignment of installation backplane – standard device
Axis controller
type
Installation backplane type Fuse Device size
E94AMxE0024
E94AZPM0044
Siba 5020106.16A I
E94AMxE0034
E94AMxE0044
E94AMxE0074
E94AZPM0094 Siba 5020106.40A II
E94AMxE0094
E94AMxE0134
E94AZPM0244
Siba 2029221.100A
(tightening torque: 3.4 Nm
(30 lb -in))
III
E94AMxE0174
E94AMxE0244