EasyManua.ls Logo

Lenze i950

Lenze i950
184 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal data
X1 Specicaon Unit min. typ. max.
SIA, SIB LOW signal V -3 0 +5
HIGH signal V +15 +24 +30
Switch-on me ms 10
Clear me ms 15 30
Input current mA 8 12
Input peak current mA 400
Input capacitance SIA
µF 5
Input capacitance SIB
Test pulse dur
aon ms 1
Test pulse interval ms 10
GS Reference potenal for SIA and SIB
Runme = St
art of rising edge at SIA, SIB unl internal HIGH signal is detected.
Switch-o me = Start of falling edge at SIA, SIB unl internal LOW signal is
detected.
Connecon descripon Basic Safety - STO
Connecon X1
Connecon type Pluggable
Max. cable cross-secon mm² 1.5
Max. cable cross-secon AWG 16
Stripping length mm 9
Stripping length in 0.35
Required tool Screwdriver 0.4 x 2.5
Electrical ins
tallaon
Funconal safety
Basic Safety - STO