Loading...
Ecodesign r
egulaon
Product informaon acc. to REGULATION (EU) 2019/1781 (ANNEX I, Secon 4)
Legend
Operang point (f; I) f = relave motor stator frequency; I = relave torque-producing current
Power losses Power losses at operang points (f; I) and in standby mode relate to the rated apparent output power.
For power losses for opons (e.g. for diagnoscs) and for accessories (e.g. mains chokes) please refer to further product
documentaon on the product web page.
Power losses
0; 25
f; I
% 2.9 2.5 1.6 1.1 1.0 1.2 0.8 4.2
0; 50
f; I
% 2.9 2.5 1.7 1.2 1.1 1.3 1.0 4.2
0; 100
f; I
% 3.1 2.7 2.0 1.5 1.5 1.7 1.5 4.5
50; 25
f; I
% 2.9 2.5 1.6 1.2 1.1 1.2 0.9 4.3
50; 50
f; I
% 3.0 2.6 1.8 1.3 1.3 1.4 1.1 4.3
50; 100
f; I
% 3.3 2.9 2.2 1.7 1.7 2.0 1.8 4.6
90; 50
f; I
% 3.1 2.7 1.9 1.4 1.4 1.5 1.2 4.4
90; 100
f; I
% 3.4 3.1 2.4 2.0 2.1 2.2 2.0 4.8
Standby losses % 1.5 1.3 0.9 0.5 0.3 0.2 0.2 1.3
Eciency level IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2
Manufacturer's name Lenze SE · Hans-Lenze-Str. 1 · 31855 Aerzen · GERMANY
Commercial registraon
number
Hannover HRB 204803
Product’s model idener I95AE137D I95AE155D I95AE175D I95AE215D I95AE222C I95AE240C I95AE255C I95AE155F
Apparent output power kVA 0.9 1.2 1.6 2.6 3.6 6.2 8.7 1.2
Indicave motor rated power
output
kW 0.37 0.55 0.75 1.5 2.2 4 5.5 0.55
Rated output current A 2.4 3.2 4.2 7 9.6 16.5 23 1.8
Maximum operang
temperature
°C 45
Rated supply frequency Hz 50
Rated supply voltage V 230 400
Switching frequency kHz 4
Rated apparent output power kVA 0.977 1.19 1.71 3.3 4.44 7.38 9.95 1.19
Technical data
E
codesign regulaon
180