Wiring the device modules
Safety modules
7
l
59
EDK94ARN24 ZH/EN 2.1
Setting the node address
The node address of the drive is calculated from the sum of all address switches in the "ON"
position.
Setting the baud rate
d c b a Baud rate
OFF ON ON OFF 10 kbit/s
OFF ON OFF ON 20 kbit/s
OFF OFF ON ON 50 kbit/s
OFF OFF ON OFF 125 kBit/s
OFF OFF OFF ON 250 kbit/s
OFF OFF OFF OFF 500 kbit/s
ON ON ON OFF 800 kbit/s
OFF ON OFF OFF 1000 kbit/s
OFF ON ON ON Auto baud
7.3 Safety modules
If the regenerative power supply module is used, safety functions are not available.
However, the SM0 module in the MSI slot is mandatory for the operation of the
regenerative power supply module.