ICN-M23 connector assignment
SinCos absolute value encoder with EnDat interface
Contact Designaon Meaning
1
U
P
sensor U
P
sensor
1
2
3
4
5
6
7
9
10
11
12
13
14
15
16
17
8
Code 0°
2 Not assigned
3 Not assigned
4 0 V sensor 0 V sensor
5 +
Temperature monitoring: KTY/PT1000
6 -
7 + UB Supply +
8 Cycle EnDat interface cycle
9 Cycle¯ Inverse EnDat interface cycle
10 GND Mass
11 Shield Encoder housing screen
12 B Track B
13 Track B inverse/-SIN
14 Data EnDat interface data
15 A Track A
16 Track A inverse
17 Dat Data inverse EnDat interface
Blower connecon
Pin assignment ICN-M17
Single−phase
Contact Name Meaning
PE PE PE conductor
1
4
2
5
6
3
+
1 U1
Fan
2 U2
3
Not assigned
4
5
6
Electrical installaon
Motor connecon
Connecon via ICN connector