Inverter mains connecon 400 V, Forced venlated motors, IP54
Product name MCA13I34- MCA14L16- MCA14L35-
Standsll torque M
0
Nm 7.00 13.5 13.5
Rated torque M
Rated
Nm 6.30 12.0 10.8
Max. torque M
max.
Nm 32.0 60.0 60.0
Rated speed n
Rated
rpm 3410 1635 3455
Max. speed n
max.
rpm 8000 8000 8000
Rated power P
Rated
kW 2.20 2.10 3.90
standsll current I
0
A 6.30 5.25 10.5
Rated current I
Rated
A 6.00 4.80 9.10
Max. current I
max.
A 24.0 19.2 36.4
Rated voltage V
N, AC
V 390 390 390
Rated frequency f
rated
Hz 120 60 120
Moment of inera J kgcm² 8.30 19.2 19.2
Eciency η
100 %
0.720 0.800 0.790
Stator terminal resistance R
UV 20°C
Ω 3.40 6.00 1.50
Stator terminal resistance R
UV 150°C
Ω 5.12 9.04 2.26
Mutual inductance L
H
mH 76.7 224 56.7
Stator leakage inductance L
1σ
mH 4.95 9.46 2.37
Rotor leakage inductance L
2σ
mH 4.39 9.30 2.32
Stator resistance R
1 UV 20°C
Ω 1.70 3.00 0.75
Rotor resistance R
2 UV 20°C
Ω 1.41 3.13 0.78
Mass m kg 12.0 16.9 16.9
Product name MCA17N17- MCA17N35- MCA19S17-
Standsll torque M
0
Nm 23.9 23.9 40.0
Rated torque M
Rated
Nm 21.5 19.0 36.3
Max. torque M
max.
Nm 100 100 180
Rated speed n
Rated
rpm 1680 3480 1700
Max. speed n
max.
rpm 8000 8000 8000
Rated power P
Rated
kW 3.80 6.90 6.40
standsll current I
0
A 9.05 18.1 15.4
Rated current I
Rated
A 8.50 15.8 13.9
Max. current I
max.
A 34.0 63.2 55.6
Rated voltage V
N, AC
V 390 390 390
Rated frequency f
rated
Hz 60 120 60
Moment of inera J kgcm² 36.0 36.0 72.0
Eciency η
100 %
0.830 0.810 0.820
Stator terminal resistance R
UV 20°C
Ω 3.04 0.76 1.38
Stator terminal resistance R
UV 150°C
Ω 4.58 1.15 2.08
Mutual inductance L
H
mH 144 36.9 80.9
Stator leakage inductance L
1σ
mH 5.59 1.40 2.61
Rotor leakage inductance L
2σ
mH 6.04 1.51 3.06
Stator resistance R
1 UV 20°C
Ω 1.52 0.38 0.69
Rotor resistance R
2 UV 20°C
Ω 1.37 0.34 0.62
Mass m kg 25.5 25.5 48.2
Technical data
Rated data
Inverter mains connecon 400 V, Forced venlated motors, IP54
74