Residual hazards
Even if notes given are taken into consideraon and protecve measures are implemented,
the occurrence of residual risks cannot be fully prevented.
The user must take the residual hazards menoned into consideraon in the risk assessment
for his/her machine/system.
If the above is disregarded, this can lead to severe injuries to persons and damage to
property!
Protecon of persons
•
The product does not provide safety-related funcons.
-
A higher-level safety system must be implemented.
-
Addional monitoring and protecve equipment complying with the safety regulaons
applicable in each case must be used.
•
The power terminals may carry voltage in the switched‐o state or when the motor is
stopped.
-
Before working, check whether all power terminals are deenergised.
•
Voltages may occur on the drive components (e.g. capacive, caused by inverter supply).
-
Careful earthing in the marked posions of the components must be carried out.
•
Risk of burns may be caused by hot surfaces!
-
Provide for a protecon against accidental contact.
-
Use the personal protecve equipment or wait unl the components have cooled
down completely!
-
Prevent contact with ammable substances.
•
There is a risk of injury due to rotang parts.
-
Before working on the drive system, ensure that the motor is at a standsll.
•
There is a danger of unintenonal starng or electrical shocks!
•
Installed brakes are no fail-safe brakes.
-
The torque may be reduced by disrupve factors that cannot be inuenced such as
ingressing oil.
Motor protecon
•
Design with plug:
-
Never disconnect the plug when energised! Otherwise, the plug can be destroyed.
-
Switch o power supply and disable inverter prior to disconnecng the plug.
•
Installed thermal detectors are no full protecon for the machine.
-
If required, limit the maximum current. Parameterise the inverter so that it will be
switched o aer seconds of operaon with I > I
rated
, especially if there is the danger
of blocking.
-
The installed overload protecon does not prevent an overload under any condions.
•
The fuses are no motor protecon.
-
Use a current-dependent motor protecon switch.
-
Use the built-in thermal detectors.
•
Too high torques cause a fracon of the motor sha.
-
The maximum torques according to catalogue must not be exceeded.
•
Lateral forces from the motor sha may occur.
-
Align the shas of motor and driven machine exactly to each other.
Safety instrucons
Residual hazards