Motor connecon
Connecon via ICN connector
Posion of the connecons
1
2
Posion Meaning
1 Power connecon
Brake connecon
PE connecon
2 Feedback connecon
Connecon of temperature monitoring
Power and brake connecon
ICN-M23 connector assignment
6-pole
Contact Name Meaning
1 BD1 Holding brake +
6
1
2
4
5
+
2 BD2 Holding brake -
PE PE PE conductor
4 U Power phase U
5 V Power phase V
6 W Power phase W
Feedback and temperature monitoring connecon
ICN-M23 connector assignment
Resolver
Contact Name Meaning
1 +Ref
Transformer windings
1
2
3
4
5
6
7
8
9
10
11
12
P
Code 0°
2 -Ref
3 +VCC ETS Power supply: electronic nameplate
4 +COS
Stator windings cosine
5 -COS
6 +SIN
Stator windings Sine
7 -SIN
8
Not assigned
9
10 Shield Encoder housing shield
11 +
Temperature monitoring: KTY/PT1000
12 -
Contact 3: only for motors and inverters which support this funcon.