ICN-M23 connector assignment
Incremental and SinCos absolute value encoder Hiperface
Contact Name Meaning
1 B Track B / + SIN
2 A¯ Track A inverse / - COS
3 A Track A / + COS
4 + UB Supply +
5 GND Mass
6 Z¯ Zero track inverse / - RS485
7 Z Zero track / + RS485
8 Not assigned
9 B¯ Track B inverse/-SIN
10 Shield Encoder housing shield
11 +
Temperature monitoring: KTY/PT1000
12 -
Assembly of ICN connectors
NOTICE
Live cables!
Destrucon of the connector.
▶
Never remove connector when voltage is being applied!
▶
Disable inverter before removing the connector!
NOTICE
Loss of the protecon class!
Malfuncons may occur.
▶
ICN connector with screwed connecon - do not remove O-ring
▶
ICN connector with SpeedTec bayonet lock - remove O-ring and dispose of it.
Mounng
1. When connecng the cable connector to the motor connector, make sure that the aids to orientaon
(pos. 1) are facing each other.
2. Tighten the box nut of the connector!
Electrical installaon
Motor connecon
Connecon via ICN connector
41