EasyManua.ls Logo

Lenze MCM Series - Page 41

Lenze MCM Series
52 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ICN-M23 connector assignment
Incremental and SinCos absolute value encoder Hiperface
Contact Name Meaning
1 B Track B / + SIN
1
2
3
4
5
6
7
8
9
10
11
12
P
Code 20°
2 Track A inverse / - COS
3 A Track A / + COS
4 + UB Supply +
5 GND Mass
6 Zero track inverse / - RS485
7 Z Zero track / + RS485
8 Not assigned
9 Track B inverse/-SIN
10 Shield Encoder housing shield
11 +
Temperature monitoring: KTY/PT1000
12 -
Assembly of ICN connectors
NOTICE
Live cables!
Destrucon of the connector.
Never remove connector when voltage is being applied!
Disable inverter before removing the connector!
NOTICE
Loss of the protecon class!
Malfuncons may occur.
ICN connector with screwed connecon - do not remove O-ring
ICN connector with SpeedTec bayonet lock - remove O-ring and dispose of it.
1
Mounng
1. When connecng the cable connector to the motor connector, make sure that the aids to orientaon
(pos. 1) are facing each other.
2. Tighten the box nut of the connector!
Electrical installaon
Motor connecon
Connecon via ICN connector
41

Table of Contents