Technical data
Standards and operang condions
Conformies/approvals
Conformity
CE 2014/35/EU Low-Voltage Direcve
2014/30/EU EMC Direcve (reference: CE-typical drive system)
Approval
cURus UL 1004-1
UL 1004-6
for USA and Canada (requirements of the CSA 22.2 No.100)
Servo motor, Lenze le no. E210321
Protecon of persons and device protecon
Degree of protecon
IP54 EN 60034-5 At the sha feedthrough
IP65 without considering the sha feedthrough, with mounted ICN
connectors
Temperature class
F (155 °C) EN 60034-1
Max. voltage load
Limit curve A of the pulse voltage IEC/TS 60034-25:2007
IVIC C@500V IEC 60034-18-41
EMC data
Noise emission EN 60034-1 A nal overall assessment of the drive system is indispensable
Noise immunity EN 60034-1 A nal overall assessment of the drive system is indispensable
Environmental condions
Climate
1K3 (-20 °C ... +60 °C) EN 60721-3-1 Storage, < 3 months
1K3 (-20 °C ... +40 °C) EN 60721-3-1 Storage, > 3 months
2K3 (-20 °C ... +70 °C) EN 60721-3-2 Transport
3K3 (-15 °C ... +40 °C) EN 60721-3-3 Operaon, without brake
3K3 (-10 °C ... +40 °C) EN 60721-3-3 Operaon, with brake
Relave humidity ≤ 85 % Without condensaon
Site altude
0 … 1000 m amsl Without power reducon
1000 … 2000 m amsl Pay aenon to the drop in power of the inverter and servo motor
Vibraon resistance
3M6 EN 60721-3-3 Operaon
Vibraon severity
A EN 60034-14
Vibraon velocity
1.6 mm/s Free suspension
Smooth running, axial runout, concentricity
Normal Class IEC 60072
Technical data
Standards and operang condions
Environmental condions