5.4 Electrical data
Supply
Operating voltage 16-35V DC
Residual ripple 15%
Current consumption appr. 130 mA (all LEDs on)
Inputs
Data inputs (Data IN) max. 35 V DC, 4.5 mA
Transmit (TX) H >= 8 V, L <= 5 V
Output enable (OE) H >= 8 V, L <= 5 V
Fig. 12 Input circuit
Outputs
Data outputs (DO) High-side driver, short-circuit proof
H >= UB - 2V, L <= 1.5 V
max. load 2 outputs each 250 mA
3 outputs each 160 mA
4 outputs each 120 mA
5 outputs each 100 mA
6 outputs each 80 mA
7 outputs each 70 mA
8 outputs each 60 mA
With a total data output load greater than 0.6 A, the back-up fuse triggers.
The supply voltage must be switched off and back on again one time in order to
activate the back-up fuse.
Data valid (DV) High side driver, short circuit proof
max. load 250 mA
Fig. 13 Output circuit
C - MOS
6,8 k
LED rot
8 - 35 V
LED Red
6,8 k
LED
grün
Transienten-
schutz
zentraler Kurzschluß –
Schutz
– Daten – – Data valid (DV) –
Kurzschluß –
Schutz
LED
gelb
protection
protection
Transient
protection
LED
Green
LED
Yellow
- Data -
Central short circuit
- Data valid (DV) -
Short circuit
Leuze electronic DLSP 160S 15