6 Installation and commissioning
6.1 Installation
➜
Fasten the DLSP in position by tightening two M4 fixing screws with washers
and circlips.
➜ Prepare the connecting cable
Cable cross-section 0.14-0.5 mm
2
Cable outside diameter 5 - 9 mm (PG 9) or 13 mm (PG 13.5)
Shielding only necessary in case of strong interference fields
➜ Unscrew the housing
➜ Guide the connecting cables through the cable glands and solder in
accordance with the plug assignment plan or
crimp the ribbon cable in the crimping plug or
insert the cores in the spring-type terminals and clamp.
Signal Description Assignment
Solder terminal
Ribbon cable
Spring terminal
PE Protective earth 1 1
U
B
Operating voltage
16 – 35 VDC
22
GND Earth
operating voltage
33
DI 8 Data input 8 4 4
DI 7 Data input 7 5 5
DI 6 Data input 6 6 6
DI 5 Data input 5 7 7
DI 4 Data input 4 8 8
DI 3 Data input 3 9 9
DI 2 Data input 2 10 10
DI 1 Data input 1 11 11
DV Data valid 15 13
DO 8 Data output 8 16 14
DO 7 Data output 7 17 15
DO 6 Data output 6 18 16
DO 5 Data output 5 19 17
DO 4 Data output 4 20 18
DO 3 Data output 3 21 19
DO 2 Data output 2 22 20
DO 1 Data output 1 23 21
OE Output enable 24 22
TX Transmit data 25 23
24/NC
25/NC
1
13
25
14
1
13
12
24
Solder terminal
Ribbon cable
Spring-type terminal
Fig. 14 Plug assignment