KRTM 3B… - 08 2016/11
Sensor adjustments via the input IN (Pin 2, not for KRTM 3B/L6…)
The following description applies to PNP switching logic!
Signal level LOW 2V
Signal level HIGH (U
B
-2V)
With the NPN models, the signal levels are inverted!
Switching threshold in center / standard sensitivity
Switching threshold near the mark / high sensitivity
Pulse stretching ON
Pulse stretching OFF
Locking the teach button via the input IN (Pin 2, not for KRTM 3B/L6…)
A static HIGH signal ( 20ms) at the teach
input locks the teach button on the sensor if
required, such that no manual operation is
possible (e.g., protection from erroneous
operation or manipulation).
If the teach input is not connected or if there is
a static low signal, the button is unlocked and
can be operated freely.
LOW
t = 20 ... 80 ms
t
HIGH
Accept 1st teach value
(background, reference value / open measurement window)
Accept 2nd teach value
(mark / close measurement window)
LOW
t = 120 ... 180 ms
t
HIGH
Accept 1st teach value
(background, reference value / open measurement window)
Accept 2nd teach value
(mark / close measurement window)
LOW
t = 220 ... 280 ms
t
HIGH
LOW
t = 320 ... 380 ms
t
HIGH
KRTM 3B