Device description
Leuze electronic MLC 520 Host/Guest 17
3.4.3
Alignment display
Approximately 5s after a protective-field interruption, the 7-segment display switches to alignment mode.
In this mode, one third of the total protective field (Host, MiddleGuest, Guest) is assigned to one of the
three horizontal segments and the state of this sub-protective field displayed as follows:
Tab.3.6: Function of alignment display
Segment Description
On All beams in the beam area are uninterrupted.
Flashing At least one, but not all beams in the beam area are uninterrupted.
Switched off All beams in the beam area are interrupted.
When the protective field has been free for about 5s, the device switches back to the display of the operat-
ing mode.