Mounting
Leuze electronic MLC 520 Host/Guest 34
6.2.6
One-sided mounting on the machine table
The safety sensor can be mounted directly on the machine table via an M5 screw on the blind hole in the
end cap. On the other end, a BT-2HF swivel mount can be used, for example, so that turning movements
for alignment are possible despite the fact that the sensor is mounted on one side. The full resolution of the
safety sensor is thus preserved on all points of the protective field down to the machine table.
Fig.6.10: Mounting directly on the machine table
WARNING
Impairment of the protective function due to reflections on the machine table!
Ä Make sure that reflections on the machine table are prevented reliably.
Ä After mounting and every day after that, check the detection capability of the safety sensor
in the entire protective field using a test rod (see chapter 9.3.1 "Checklist – periodically by
the operator").