Page 26
CONNECTING TO NETWORK VIA PC ACCESS
To access the controller over the network via PC Access:
1. Open an OmniPro II account file.
2. Click Configure >> Network.
If you are connecting from the local network, enter the controller’s IP address under “Network IP Address or
Domain Name”.
If you are connecting from the Internet, enter either the public IP address (the way to reach your local network via
the Internet) or domain name (e.g. www.homeauto.com).
3. Enter the port number that is configured for the controller.
4. Select the Encryption tab. Enter the two part encryption key as it is displayed on the console.
5. Select OK.
6. Click Connect >> Network >> Connect. PC Access should change from “Off-Line” to “On-Line”.
The “Modem” item on the main menu has been replaced with the “Connect” item. The submenu under “Connect” then allows
selection of “Modem”, “Serial” or “Network”. When an account file is opened, the connection type will default to “Serial”.
To connect to an OmniPro II controller on
a local network using LEVITON PC
Access, under Configure >> Network
enter the controller’s IP address:
(i.e. 192.168.0.101)