To change a zone type, press the ' # ' key, then use the arrow keys to scroll through the list of zone types. Press the ' # ' key to
select a new type
. The display shows:
SELECT TYPE: 1
PERIMETER ↕
ZONE RESPONSE TIME
All zones, in the OmniPro II are set to a 300 millisecond fixed response time.
ZONE TYPES
ZONE TYPE NUMBER DESCRIPTION
ENTRY/EXIT 0 Entry/Exit
PERIMETER 1 Perimeter
NIGHT INT 2 Night Interior
AWAY INT 3 Away Interior
2X ENTRY DELAY 4 Double Entry Delay
4X ENTRY DELAY 5 Quadruple Entry Delay
LATCH PERIM 6 Latching Perimeter
LATCH NIGHT INT 7 Latching Night Interior
LATCH AWAY INT 8 Latching Away Interior
PANIC 16 Panic
POLICE EMERG 17 Police Emergency
SILENT DURESS 18 Duress
TAMPER 19 Tamper
LATCH TAMPER 20 Latching Tamper
FIRE 32 Fire
FIRE EMERG 33 Fire Emergency
GAS 34 Gas Alarm
AUX EMERG 48 Auxiliary Emergency
TROUBLE 49 Trouble
FREEZE 54 Freeze
WATER 55 Water
FIRE TAMPER 56 Fire Tamper
AUXILIARY 64 Auxiliary
KEY SWITCH 65 Keyswitch Input
ENERGY SAVER 80 Programmable Energy Saver Module
OUTDOOR TMP 81 Outdoor Temperature
TEMPERATURE 82 Temperature
TEMP ALARM 83 Temperature Alarm
HUMIDITY 84 Humidity
ER OUTDOOR TMP 85 Extended Range Outdoor Temperature
ER TEMPERATURE 86 Extended Range Temperature
ER TEMP ALARM 87 Extended Range Temperature Alarm
LATCHING ZONE TYPES
When any device (other then FIRE or GAS) is connected to SWITCH 12V or a Switched Power Output, the zone must be
configured as one of the LATCHING ZONE TYPES (latching perimeter, latching night interior, latching away interior, and
latching tamper). LATCHING ZONE TYPES ignore the status of that zone during power cycles.
Used primarily when the FIRE ALARM VERIFICATION feature is being used or if more than one area is being protected. This
type will ignore the status of LATCHING ZONES (i.e. Glassbreak Detectors) when the power is switched to reset devices.