Page 56
MODULE 2 TYPE - MODULE 4 TYPE
Module 2 is the module with the jumper set to 2, and so on. Set each module type from the list of “Module Types”.
SERIAL 1 RATE
"Serial 1 Rate" selects the baud rate used for the first built-in serial interface (J1 Serial) on the OmniPro II controller. Select the
baud rate for the first built-in serial interface from the list. Use the arrow keys to select the baud rate then press the ' # ' key.
BAUD RATE NUMBER
75 baud 1
150 baud 2
300 baud 3
600 baud 4
1200 baud 5
2400 baud 6
4800 baud 7
9600 baud 8 (default)
SERIAL 1 FUNCTION
The "Serial 1 Function" selects the communication protocol used for the first built-in serial interface (J1 Serial) on the OmniPro II
controller. Select the function for the first built-in serial interface from the list. Use the arrow keys to select the function then
press the ' # ' key.
FUNCTION TYPES NUMBER DESCRIPTION
OMNI-LINK 3 Serial communication using the Omni-Link protocol
PRO-LINK 4 Serial communication using the Pro-Link protocol
UPB 5 Serial communication using the UPB protocol
RADIO RA 6 Serial communication using the RadioRA protocol
NUVO CONCERTO 7 Serial communication using the NuVo Concerto protocol
RUSSOUND 8 Serial communication using the Russound protocol
CENTRALITE 9 Serial communication using the CentraLite protocol
VIZIA RF Z-WAVE 10 Serial communication using the Z-Wave protocol
LEVITON HI-FI 11 Serial communication using the LEVITON Hi-Fi protocol
NUVO GRAND CONCERTO 12 Serial communication using the NuVo Grand Concerto protocol
NUVO ESSENTIA/SIMPLESE 13 Serial communication using the NuVo Essentia/Simplese protocol
XANTECH 14 Serial communication using the Xantech protocol
SPEAKERCRAFT 15 Serial communication using the Speakercraft protocol
PROFICIENT 16 Serial communication using the Proficient protocol
Note:
The NuVo Grand Concerto, Speakercraft, or Proficient audio systems can not be connected to the first built-in serial port
(J1 Serial) on the OmniPro II controller. It must be connected to the (J2 Serial - J5 Serial) built-in serial port on the OmniPro II
controller.
SERIAL 2 - SERIAL 5 RATE
"Serial 2 Rate" - “Serial 5 Rate" selects the baud rate used for the second, third, fourth, and fifth built-in serial interface ports (J2
Serial - J5 Serial, respectively) on the OmniPro II controller. Select the baud rate for the built-in serial interface from the list.
SERIAL 2 FUNCTION
The "Serial 2 Function" selects the communication protocol used for the second built-in serial interface ports (J2 Serial) on the
OmniPro II controller. Select the function for the built-in serial interface from the list.
WEB VERSION