Lexicon
5-7
When a front panel switch is held down for more than 1/2 second, the bottom display will read "Held"
instead of "Pressed". See example below:
Gain Button
Held
Note: When the NO< button is held for more than 1/2 second the test will exit and display the following:
Diags: Tests
< Switch
Footswitches:
For this test a Lexicon Dual Momentary Footswitch (Lexicon P/N 750-09277), or equivalent, must be
inserted into the Footswitch ¼ jack on the back of the MPX G2
The same approach is used for the Footswitches except that Held is not displayed when a footswitch is held
down for more than ½ second. When the left footswitch is pressed, the display reads:
Foot SW 1 Ring
Pressed
When the left footswitch is released the display reads:
Foot SW 1 Ring
Released
Press the right footswitch, the display will now read:
Foot SW 2 Tip
Pressed
When the right footswitch is released the display reads:
Foot SW 2 Tip
Released
Insert Return Jacks:
Insert a ¼” Phone Plug to the Left Insert Return Jack on the back of the MPX G2, the display reads:
Left Insert
Inserted
When the ¼” Phone Plug is removed from the Left Insert Return Jack, the display reads:
Left Insert
Removed
Next insert the ¼” Phone Plug to the Right Insert Return Jack on the back of the MPX G2, the display
reads:
Right Insert
Inserted
When the ¼” Phone Plug is removed from the Right Insert Return Jack, the display reads: