15
PCM 80 Version 1.10 MIDI Implementation Details
Lexicon
0x16 Parameter Specific Response
PCM 80 to Host only. This dump returns information about a specific parameter. It is useful for an editing
program that doesn’t know the count, range or name of a parameter.
Byte # Byte Value Description Notes
1 F0 SysEx ID
2 06 Lexicon ID
3 07 PCM 80 ID
4 0iii iiii Device ID
5 0x16 Parameter Specific
Data
6 0n Type 0=System;1=Patchable; 2=Non-patchable
7 0n Offset
8 0iii iiii Flags There are currently two bits defined in this field: Bit 0 (0x01) Parameter
supports tempo mode. Bit 3 (0x08) Parameter is not patchable. This
overrides the type field.
9-20 0xxx xxxx 2-byte row Name See Overview for information on strings.
21-32 0xxx xxxx 12-byte parameter
name See Overview for information on strings.
33 0n Least significant
nibble of the maximum
parameter value (16-bit
unsigned) In some cases, algorithms have internal parameters which are not
controllable from MIDI or from the front panel. In those cases, maximum
value=0.
34 0n Next nibble
35 0n Next nibble
36 0n Most-significant nibble
37 0xxx xxxx Destination List ID This is of interest only when an external editing program is directly
editing the Effect SysEx packet 0x02, which requires this Destination
List ID and Destination List index. The values obtained here should be
plugged into that packet where they determine the display position of
the parameter in the edit matrix. If the parameter is not patchable, this
field will be set to 0x7F.
38 0xxx xxx Destination List Index See above note for Destination List ID.
39 0xF7 End of SysEx
0x17 Parameter Display Response
PCM 80 to Host only. This dump returns the current display for a specific parameter. It should be useful
for an editing program that doesn’t know the display specifics for a parameter.
Byte # Byte Value Description Notes
1 F0 SysEx ID
2 06 Lexicon ID
3 07 PCM 80 ID
4 0iii iiii Device ID
5 0x17 Parameter display
data
6 0n Parameter type See Parameter Dump (0x0B).
7 0n Parameter number Some parameter numbers are algorithm dependent. See the appropri-
ate algorithm description.
8-27 0iii iiii 20-character
display string
28 0xF7 End of SysEx