20
LexiconPCM 80 Version 1.10 MIDI Implementation Details
0x24 Soft Row Display Response
This dump is only transmitted by the PCM 80 as the result of an inquiry. It is a support function for the
Soft Row Assignment Dump. It returns substitute row and column values (used as bytes 7 and 8 in the
Soft Row Assignment message) along with the text name of the parameter block to be placed there. The
displays apply only to the currently loaded algorithm.
In many cases, related parameters, such as Master parameters for displays, are stacked up onto a single
matrix slot. A descriptive slot name for the entire parameter group is used in soft row assignments. This
message allows a program to determine the name.
Byte # Byte Value Description Notes
1 F0 SysEx ID
2 06 Lexicon ID
3 07 PCM 80 ID
4 0iii iiii Device ID
5 0x24 Soft Row
Display Message
6 0iii iiii Algorithm iD
7 0iii iiii Number of value
soft row assignments
for current algorithm Only this many of the following descriptors should be used. The message
reserves room for up to 64 descriptors
8-29 0iii iiii 22-Byte descriptor
for soft row assigment 1 byte=Substitute row. Plug this into byte 7 of the Soft Row assignment
message
1 byte=Substitute column. Plug this into byte 8.
20 bytes=Display string. A text descriptor of the parameter block to be
assigned to the soft row. This is the same string that appears when
editing the soft row from the front panel. In some cases, multiple
parameters may be grouped into a single location on the matrix.
30-1415 0iii iiii Remaining descriptors
1416 0xF7 End of SysEx
0x7C Failure Response
PCM 80 to Host only. This message tells the host that the PCM 80 was unable to service a particular
request, for example a request for an effect that is not present. Note that the failure response is only
returned when the host has transmitted a properly formatted request. Any partial or corrupted request
receives no response.
Byte # Byte Value Description Notes
1 F0 SysEx ID
2 06 Lexicon ID
3 07 PCM 80 ID
4 0iii iiii Device ID
5 0x7C Failure
6 0xF7 End of SysEx

Table of Contents