19
PCM 80 Version 1.10 MIDI Implementation Details
Lexicon
0x21 Patch Display Response
PCM 80 to Host only. This dump returns the current display for a specified patch at a specified input value.
It is useful for an editing program that doesn’t know the display specifics for a parameter.
Byte # Byte Value Description Notes
1 F0 SysEx ID
2 06 Lexicon ID
3 07 PCM 80 ID
4 0iii iiii Device ID
5 0x21 Patch display data
6 0n Patch (0-9)
7 0n Pivot point (0-127) This should be an assigned point.
8-22 0iii iiii 15-character
display string See Overview for information on ASCII characters.
23 0xF7 End of SysEx
0x22 Matrix Mapping Response
PCM 80 to Host only. This dump is a response to a request for information. The request holds Destination
List ID and Destination List Index. This message returns the parameter that is mapped to that location
in the edit matrix. These are required when translating to and from the stored effect format.
Byte # Byte Value Description Notes
1 F0 SysEx ID
2 06 Lexicon ID
3 07 PCM 80 ID
4 0iii iiii Device ID
5 0x22 matrix mapping data
6 0iii iiii Destination List ID Used in the single effect packet.
7 0iii iiii Destination List Index Used in the single effect packet.
8 0iii iiii Parameter type See Parameter Dump .
9 0iii iiii Parameter offset Dependent on parameter type and algorithm.
10 0xF7 End of SysEx
0x23 Adjust Knob Value Dump
Bidirectional. This dump allows the Adjust knob value to be transmitted or received.
Byte # Byte Value Description Notes
1 F0 SysEx ID
2 06 Lexicon ID
3 07 PCM 80 ID
4 0iii iiii Device ID
5 0x23 Adjust knob value
6 0iii iiii Knob Value Value within range of 0-127
7 0xF7 End of SysEx

Table of Contents