Post 4-State bar code descriptors
89
Swiss postal
/BarHeight must be:
• Greater than or equal to 20 mm for module widths less than or equal to 0.45 mm (0.0177
inches)
• Greater than or equal to 23 mm for module widths greater than 0.45 mm (0.0177 inches)
Key Range Default value Description
/Symbology — /SwissPostal Identifies the bar code symbology
/HeightUnits 0–4 (dec) 4 (dec)
[integer]
Specifies the units used for /BarHeight
dimensions
0 = Use default value
1 = 1/300 inch units
2 = 1/600 inch units
3 = 1/1200 inch units
4 = 1/720 inch units
/Height See the notes that
follow the table.
653 (dec)
[integer]
Sets the bar height
/WidthUnits 0–4 (dec) 2 (dec)
[integer]
Specifies the units used for /BarWidth and
/SpaceWidth dimensions
0 = Use default value
1 = 1/300 inch units
2 = 1/600 inch units
3 = 1/1200 inch units
4 = 1/720 inch units
If /WidthUnits is specified, then it takes
precedence over /Units.
/Width 0.40–0.51 mm
0.0157-0.0200
inches
11 (dec)
[integer]
Sets the bar width
The default value is 11/600 inch.
/SpaceWidth 0.40–0.51 mm
0.0157-0.0200
inches
11 (dec)
[integer]
Sets the space width
The default value is 11/600 inch.
/QuietZone [int int] [150 150]
[array of
integers]
Optional
Sets the quiet zone in /Units
/Units — — Optional
The value is 1/600 inch