Post 4-State bar code descriptors
88
Dutch Post 4-State bar code
/QuietZone [int int] [150 150]
[array of
integers]
Optional
Sets the quiet zone in /Units
/Units — — Optional
The value is 1/100 mm
Key Range Default value Description
/Symbology — /DutchPostal Identifies the bar code symbology
/Bars 38–63 (dec) 50 (dec)
[integer]
Sets the bar width to 1/100 mm
/Spaces 20–24 (dec) 22 (dec)
[integer]
Sets the number of bars that print per inch
/SyncBarHeight 102–152 (dec) 127 (dec)
[integer]
Sets the synchronization bar height in
1/100 mm
/UpDnBarHeight 160–216 (dec) 188 (dec)
[integer]
Sets the upward and downward bar height in
1/100 mm
/QuietZone [int int] [150 150]
[array of
integers]
Optional
Sets the quiet zone in /Units
/Units — — Optional
The value is 1/100 mm
Key Range Default value Description