S-Device Supervisor Object
14
17200138_002_C0 – (2016-10) –
Leybold
Data Component Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Device Exception
Detail Alarm Size
0 0 0 0 0 1 0 0
Device Exception
Detail Alarm 0
Pirani
0 0 0 0 0 0 0 0
Device Exception
Detail Alarm 1
Pirani
0 0 0 0 0 0
Electronics
Failure
0
Device Exception
Detail Alarm 2 Hot
cathode
0 0 0 0 0 0
Filament 2
Failure
Filament 1
Failure
Device Exception
Detail Alarm 3 Hot
cathode
0 0 0 0 0 0
Electronics
Failure
0
Manufacturer
Exception Detail
Alarm Size
0 0 0 0 0 0 0 1
Manufacturer
Exception Detail
Alarm
0 0 0 0 0 0 0
serial
comm.
Data Component Bit 7...4 Bit 3 Bit 2 Bit 1 Bit 0
Device Exception
Detail Warning Size
0 0 1 1 0
Device Exception
Detail Warning 0 –
Sensor Class
Status Extension
0 0
Under-
range
Exceeded
Overrange
Exceeded
Reading
Invalid *)
Device Exception
Detail Warning 1
Pirani
0 0 0 0 0
Device Exception
Detail Warning 2
Pirani
0 0 0
Electronics
Warning
0
Device Exception
Detail Warning 3
Hot cathode
0 0 0
Filament 2
Warning
Filament 1
Warning
Device Exception
Detail Warning 5
Hot cathode
0
Pressure
too high
for degas
0 0 0
Manufacturer
Exception Detail
Warning Size
0 0 0 0 1
Manufacturer
Exception Detail
Warning
0 0 0 0
serial
comm.
Warning
*) Logical inversion of Reading Valid.
These Boolean attributes are used to enable (1) or disable (0) the S-Device Super-
visor object’s process of setting Exception bits. When disabled, corresponding bits
are never set; and, if they were set, disabling clears them. Also, alarm and warning
states are not retained; when enabled, bits will be set only if the corresponding
condition is true.
The default state for these Enable attributes is enabled (1).
Device Exception Detail
Alarms and Manufacturer
Exception Detail Alarms
Format
Exception Detail Warning
Alarm Enable and Warning
Enable