LGE LCD Division LG(51)
Establish:
Reform:
LC12C Adjust Specification
LG Electronics
â–ª W/B adj. Objective & How-it-works
- Objective: To reduce each Panel’s W/B deviation
- How-it-works: When R/G/B gain in the OSD is at 192, it means the panel is at its Full Dynamic
Range. In order to prevent saturation of Full Dynamic range and data, one of
R/G/B is fixed at 192, and the other two is lowered to find the desired value.
-Adj. condition : normal temperature
1) Surrounding Temperature: 25±5℃
2) Warm-up time: About 5 Min
3) Surrounding Humidity: 20% ~ 80%
5.1.2 Equipment
1) Color Analyzer: CA-210 (LED Module : CH 14)
2) Adj. Computer(During auto adj., RS-232C protocol is needed)
3) Adjust Remocon
4) Video Signal Generator MSPG-925F 720p/216-Gray(Model:217, Pattern:78)
→ Only when internal pattern is not available
â–ªColor Analyzer Matrix should be calibrated using CS-1000
5.1.3 Equipment connection MAP
5.1.4 Adj. Command (Protocol)
<Command Format>
START 6E A 50 A LEN A 03 A CMD A 00 A VAL A CS A
Color Analyzer
Computer
Pattern Generator
※
※If TV internal pattern is used, not needed
Signal
Source
Probe
RS-232C
RS-232C
RS-232C