82
ENG
ENGLISH
CONTROLLING THE MULTIPLE PRODUCT
27. On Timer Input (Command: f u)
To select an external input for the current On Time
setting and add a new schedule or change the
existing schedule.
Transmission
[f][u][ ][Set ID][ ][Data1][Cr]
[f][u][ ][Set ID][ ][Data1][Data2][Cr]
Data (Add schedule)
20: Input (AV)
40: Component
60. RGB
70: DVI-D
90: HDMI (HDMI1)
70: DVI-D
90: HDMI (HDMI1)
C0: Display Port
91: HDMI2/SDI
B0:SuperSign
Data1 (Change schedule)
1. f1h to f4h (Read data)
F1: Select the 1st schedule input
F2: Select the 2nd schedule input
F3: Select the 3rd schedule input
F4: Select the 4th schedule input
F5: Select the 5th schedule input
F6: Select the 6th schedule input
F7: Select the 7th schedule input
Data2
20: Input (AV)
40: Component
60: RGB
70: DVI-D
90: HDMI (HDMI1)
C0: Display Port
91: HDMI2/SDI
B0:SuperSign
* To read the schedule input, enter FFH for [Data2].
If no schedule is available for [Data1] when
attempting to read or change the schedule data, the
text NG will be displayed and the operation fails.
(Example 1: fu 01 60 - Move each schedule input
down one row and save the 1st schedule input in
RGB mode.)
(Example 2: fu 01 f1 ff - Read the 1st schedule input.)
(Example 3: fu 01 f3 20 - Change the 3rd data
schedule input to the current On Time and AV input.
If there is no third schedule, the text NG will be
displayed and the operation fails.)
* This function is supported only when 1 (Year/Month/
Day), 2 (Hour/Minute/Second), On Time (Repeat
Mode/Time) are set.
** It may not be supported depending on the model.
Acknowledgement
[u][ ][Set ID][ ][OK/NG][Data][x]
[u][ ][Set ID][ ][OK/NG][Data1][Data2][x]
28. Sleep Time (Command: f f)
To set the Sleep Time.
Transmission
[f][f][ ][Set ID][ ][Data][Cr]
Data 00: Off (Sleep Timer off)
01: 10 min.
02: 20 min.
03: 30 min.
04: 60 min.
05: 90 min.
06: 120 min.
07: 180 min.
08: 240 min.
Acknowledgement
[f][ ][Set ID][ ][OK/NG][Data][x]
29. Power On Delay (Command: f h)
To set the schedule delay when the power is turned
on. (Unit: Second)
Transmission
[f][h][ ][Set ID][ ][Data][Cr]
Data 00 to 64: min. 0 to max. 100 (sec.)
Acknowledgement
[h][ ][Set ID][ ][OK/NG][Data][x]
30. Automatic Standby (Command: m n)
To set the Automatic Standby function.
Transmission
[m][n][ ][Set ID][ ][Data][Cr]
Data 00: Off (No off after 4 hours)
01: 4 Hours (Off after 4 hours)
Acknowledgement
[n][ ][Set ID][ ][OK/NG][Data][x]

Table of Contents