1.3 Specifications
Note :
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 27°C(80.6°F) DB / 19°C(66.2°F) WB
Outdoor 35°C(95°F) DB / 24°C(75.2°F) WB
- Heating Temperature : Indoor 20°C(68°F) DB / 15°C(59°F) WB
Outdoor 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Piping Length : Interconnected Pipe Length = 7.6m(25ft)
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Due to our policy of innovation some specifications may be changed without notification.
Combination
Outdoor unit
AUUW24GD2
[LUU247HV]
AUUW42GD2
[LUU427HV]
Indoor unit
ATNH24GPLE2
[LCN247HV]
ATNH42GMLE2
[LCN427HV]
Capacity
Cooling
Min.∼Rated∼Max.
kW 2.84 ~ 7.03 ~ 7.81 5.00 ~ 12.3 ~ 13.8
Min.∼Rated∼Max.
Btu/h 9,700 ~ 24,000 ~ 26,700 17,100 ~ 42,000 ~ 47,100
Heating
Min.∼Rated∼Max.
kW 3.20 ~ 7.91 ~ 8.80 5.00 ~ 13.8 ~ 15.4
Min.∼Rated∼Max.
Btu/h 10,900 ~ 27,000 ~ 30,000 17,100 ~ 47,000 ~ 52,600
Power Input
Cooling Rated kW 1.91 4.07
Heating Rated kW 2.60 4.05
Running Current
Cooling Rated A 10.5 19.0
Heating Rated A 14.2 22.0
EER / COP Btu/h·W 12.56 / - 10.31 / -
SEER / HSPF Btu/h·W 17.00 / 9.70 17.00 / 8.60