14
EN
Restarting the Air 
Conditioner Automatically
When the air conditioner is turned on again after a 
power failure, this function restores the previous 
settings.
Disabling Auto Restart
1
Open the front panel.
 x Lift up both sides of the panel slightly.
2
Press the ON/OFF button and hold it for 6 
seconds, then the unit will beep twice and the 
lamp will blink twice 4 times.
 x To re-enable the function, press the ON/OFF 
button and hold it for 6 seconds. The unit will 
beep twice and the lamp will blink 4 times.
NOTE
 x The feature may be changed according to the type 
of model.
 x If you press and hold the ON/OFF button for 3 – 5 
seconds, instead of 6 seconds, the unit will switch 
to the test operation. In the test operation, the unit 
blows out strong cooling air for 18 minutes and 
then returns to factory default settings.
Using the Mode Function
This function allows you to select the desired 
function.
Cooling & Heating Model
Cooling Mode
Auto Changeover Mode
Dehumidification Mode
Heating Mode
Fan Mode
Cooling Mode
1
Turn the appliance on.
2
Press MODE button repeatedly to select the 
Cooling Mode.
 x
 is displayed on the display screen.
3
Press   or   button to set the desired 
temperature.