LG GHD30 - 4. TROUBLESHOOTING GUIDE; Common Dehumidifier Issues and Solutions

LG GHD30
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.
TROUBLESHOOTING
GUIDE
|
|
сомотом
|
cause
|
REMEDY
O
1.
Dehumidifier
does
not
start.
(Both
No
power
Check
power
supply
at
outlet.
compressor
and
fan
motor
do
not
Correct
if
none.
operate.)
Poor
plug
contact
at
outlet.
Install
plug
properly
or
replace
it.
Bucket
is
full.
If
Auto Shut
Off
lights,
empty
the
bucket
and
replace
properly.
Humidity
control
is
at
Off
position
Turn
the
humidity
control
switch
toward
Max.
Wire
disconnected
or
loose
Connect
wire.
Refer
to
wiring
diagram
for
terminal
identification.
Repair
or
replace
loose
terminal.
Capacitor.
Test
capacitor.
(Discharge
capacitor
before
testing.)
Replace
if
not
within
+10%
of
manufacturer's
rating.
Replace
if
shorted,
open,
or
damaged.
2.
Motor
runs
but
compressor
does
not
Voltage
(115V
+
10%)
It
must
be
between
103.5V
and
126.5V.
If
run.
not
within
limits,
call
an
electrician
Wiring
Check
the
wire
connections;
If
loose,
repair
or
replace
the
terminal.
If
the
wires
are
disconnected,
refer
to
wiring
diagram
for
identification,
and
replace
the
wires.
Check
the
wire
connections;
If
not
according
to
the
wiring
diagram,
correct
the
connections.
Rotary
switch
Check
for
continuity,
refer
to
the
wiring
diagram
for
terminal
identification.
Replace
the
switch
if
the
circuit
is
open.
Defrost
control
The
Defrost
Control
senses
frost
build-up
on
the
evaporator
coil
and
automatically
shuts
off
the
compressor.
The
fan
continues
to
run,
drawing
air
across
the
coil,
and
melting
the
frost.
When
the
coil
is
defrosted,
the
compressor
automatically
restarts,
and
dehumidifying
resumes.
Capacitor
Check
the
capacitor.
(Discharge
capacitor
before
servicing.)
Replace
if
not
within
+10%
of
manufacturer's
rating.
Replace
if
shorted,
open,
or
damaged.
Compressor
Check
the
compressor
for
open
circuit
or
ground.
If
open
or
grounded,
replace
the
compressor.
Overload
protector
(OLP)
Check
the
compressor
OLP
if
externally
mounted.
Replace
if
open.
(If
the
compressor
temperature
is
high,
remove
OLP,
cool,
and
retest.)
3.
Does
not
defrost
control.
Defrost
control
is
defective.
Check
defrost
control,
replace
it.
4.
Insufficient
dehumidification
Low
relative
humidity
Turn
dehumidifier
off.
Poor
air
circulation
Move
dehumidifier
to
obtain
free
and
unobstructed
air
circulation.
H/E
clogged
with
dust
and
dirt
Clean
evaporator
and/or
condenser
assembly
Air
filter
is
dirty.
Motor
is
not
operating.
Check
Motor,
repair
or
replace
it.