Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1-6
SERVICE INFORMATION FOR EEPROM (AMP PART)
POWER ON
FLD no disc status
Remote control ‘2’ + Front ‘STOP’
push same timing during 5s
FLD ‘OP-0….
Use arrow key ( ) move
to appropriate position and make
changes
Press ENTER key once
FLD ‘write ok’ or ‘up ok’
Remote control ‘2’ + Front ‘STOP’
push same timing
FLD display E2P CLR or EP CLR
Auto power off
MODEL : HT303
NAME HEX
OPT 1 06
OPT 2 4A
OPT 3 21
OPT 4 27
OPT 5 20
MODEL : HT353
NAME HEX
OPT 1 06
OPT 2 4A
OPT 3 20
OPT 4 27
OPT 5 20
DETECT NEW EEPROM