Service Bulletin about service compressor replacement FC, FLA, FLB → FLS  
 (Compressor replacement guide) 
Service Bulletin 
Applicable for Serial Number : 
1. Repair Instruction 
※ FC, FLB, FLA→ FLS for compressor service integration 
-. Case 1) The models with FC75LBNA, FLB075LANA, FLB075LBNA and FLA075LANA  compressor can be replaced with the FLS 
compressor and must be changed together with PCB software upgrade for the FLS compressor. 
   Case 2) FLS compressor must be replaced with the FLS compressor.  
   Case 3) Some PCB’s must be replaced and then have the upgraded software installed for the FLS compressors. 
-. You can proceed with the software upgrade by referring to the quick guide included with the compressor as shown below.(Page3-4) 
-. This unit has the  New Cover PTC so pay attention to paragraph 4 of the Quick SW Update Guide (page 4) 
-. PCB’s must be replaced if their production date is before that specified on  pages 8.9. 
Page 1 
Applicable for models :  FC75LBNA, FLB075LANA, FLB075LBNA and FLA075LANA  compressor  
Bulletin Type  : SVC Notice      Parts     Others   Applicable only with symptoms            with every repair    
Symptoms   SVC Compressor standardization 
Picture   N/A 
Cause   N/A 
 
https://youtu.be/Z5oMBH3CSK0  
■ Training video 
Product : Ref 
Bulletin # :CNZ201900235-04 
Release Date : 2019.10.25