4. Soft Dry Operation Mode
During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 0.5°C, the com-
pressor OFF temperature is the setting temperature minus 0.5°C.
When the room temperature rises over the compressor ON temperature, the operation mode is switched to
the Cooling operation.
When the room temperature falls the compressor OFF temperature, the operation mode is switched to the
Soft Dry Operation.
The operation diagram is shown below.
-14-
INDOOR FAN
Selecting
fan speed
LOW
LOW LOW
ON ON ONOFF OFF
OFF LOWOFF
Operation
Cooling
Dry Operation
COMPRESSOR
SETTING TEMP.+0.5°C
(COMP. ON)
ROOM TEMP.
SETTING TEMP.
(COMP. OFF)
3.2 minutes
10 minutes
40 seconds 40 seconds
3.2 minutes
maximum
10 minutes
maximum
3 minutes
5. Cooling Mode with Sleep Mode Auto Control
When selecting the Cooling( ) combined with the Sleep Mode Auto Control( ), the operation diagram is
as following.
The setting temperature will be automatically raised by 1°C 30 minutes later and by 2°C 1 hour later.
The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.