LG LS-E0960CL - Test Running and Performance Evaluation; Power Connection and Remote Setup; Outdoor Unit Mounting and Performance Check

LG LS-E0960CL
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-36-
A
Oil trap
Outdoor unit
Indoor unit
B
A
B
Outdoor unit
Indoor unit
7. Pipe length and the elevation
• Capicity is based on standard length and maximum allowance length is the basis of reliability.
• Oil trap should be installed per 5~7 meters.
• Numerical value in "( )" is for Rotary Comp. model.
CAUTION
In case more than 5m
Max. Piping
Length
Ⓐ (m)
Capacity
(Btu/h)
7~12K 15 7 4 20
18K 30(20) 15(10) 4 or 5 40
24K~30K 30 15 4 or 5 40
Max.
Elevation
Ⓑ (m)
Standard
Length(m)
Additional Refrig-
erant
(g/m)