-15-
6. Auto Operation
The operation procedure is as following.
If initial mode is decided, that mode is continued despite of the room temperature changing.
Auto Operation for Cooling
Press Start/Stop Button
Select Auto Operation Mode
Check the Room temperature
Operation mode
Indoor fan speed are automatically decided by Fuzzy rule.
Setting temperature
Intake-air
temperature
Operation Mode
Over below
21
°
C24
°
C
Soft Dry
below 21
°
C
Heating
Over 24
°
C
Cooling
~
Intake-Air temp.
INDOOR FAN SPEED
COMPRESSOR ON OFF
Fuzzy Speed
ON OFF
Setting Temp. +0.5°C
(Compressor OFF)
Setting Temp. -0.5°C
(Compressor ON)
More than
3 minutes
Intake-air Temperature Setting Temperature
Over 26°C25°C
Over 24°C~below 26°C Intake air -1°C
Over 22°C~below 24°C Intake air -0.5°C
Over 18°C~below 22°C Intake air temperature
below 18°C18°C
Over 18°C~below 30°C Fuzzy control
below 18°C18°C Fuzzy control
over 30°C30°C Fuzzy control
Operation Condition
When Auto Operation
initial start
Controlled by
Fuzzy logic
1/f rhythm
Fan Speed Air DirectionControl
When Switch to Auto
Operation