Single Zone Extended Piping Wall Mounted Installation Manual
Due to our policy of continuous product innovation, some specifications may change without notification.  
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
ELECTRICAL SYSTEM INSTALLATION
Controller Options
Handheld Remote Controller
Single Zone Extended Piping Wall Mounted systems include a wireless handheld remote controller (Part No. 
AKB74955602). Optional LG-suppled wired controllers are available. See “Functions, Controls, Options”in the 
Engineering Manual, or contact an LG representative for more information. 
Wireless Handheld Remote Controller features: 
• Display Panel: Displays operation conditions.
• On / Off Button: Turns system operation on and off.
• Mode Button: Selects the operation mode: Cooling, 
Heating, Auto, Dry (Dehumidification), or Fan. 
• Temp Up / Down Buttons: Adjusts the desired room 
temperature in the different modes.
• Fan Speed Button: Sets desired fan speed.
• Reset: Initializes the handheld remote control 
settings.
Dry Contact 
A Dry Contact can also be connected to the Extended Piping indoor 
unit using the CN-CC connection on the indoor unit PCB. The Dry 
Contact DC is shipped with a specific connector that is used to 
connect to the indoor unit.
Central Controller
Additionally, Single Zone Extended Pipe systems can be connected 
to a central controller if a PI-485 VNet Accessory is installed in the 
outdoor unit. See the Central Controller manual for wiring specifica-
tions.
&RQQHFWLRQVDQG6SHFL¿FDWLRQV&RQWUROOHU2SWLRQV
Figure 84: Schematic of a Single Zone System When the Wiring is GREATER THAN 130 Feet.
Wired Controller Connections 
Optional controllers (see the Single Zone Extended Piping Wall-Mounted Engineering Manual, or contact an 
LG representative for more information) connect to the Single Zone Extended Piping Wall-Mounted indoor unit 
in one of two different ways.
1.  LG Wired Remote Extension Cable with Molex plug (PZCWRC1; sold separately) that connects to the 
CN-REMO terminal on the indoor unit PCB.  
2.  Field-supplied controller cable that connects to the indoor unit 
terminal block (must be at least UL2547 or UL1007, and at least 
FT-6 rated if local electric and building codes require plenum 
cable usage). Communication cable from indoor unit to remote 
controller(s) is to be 22 AWG, 3-conductor, twisted, stranded, 
unshielded. Wiring must comply with all applicable local and 
national codes. 
Figure 85: AKB74955602 
Wireless Handheld Remote 
Controller. 
:KHQXVLQJ¿HOGVXSSOLHGFRQWUROOHUFDEOHPDNHVXUHWRFRQQHFWWKH\HOORZWR\HOORZFRPPXQLFDWLRQVZLUHUHGWRUHG9SRZHUZLUHDQGEODFNWR
black (ground wire) terminals from the remote controller to the indoor unit terminal blocks.      
Verify the connectors are properly inserted.
C/BOX Cable (Plug type)
Extension cable
To Indoor Unit
CN-REMO 
Terminal
TEMP
FAN
SPEED
OPER
MODE
Figure 86: PZCWRC1 LG Wired Remote Extension Cable. 
Figure 87: Wired Controller Connections on the Indoor Unit Terminal 
Block. 
Power 
Supply
1(L1) (Power, L)
2(L2) (Neutral, N)
G (Ground)
Power Flow: L ĺ N
Diagram is an example of communication and power 
cables when the wiring is GREATER THAN 130 feet. 
Terminals may be labeled differently depending on the model.
Outdoor and Indoor Unit a
earances ma
 var
 de
endin
 on the model.
Communication Flow: Comm ĺ N
3 (Communications)
GREATER THAN 130 feet: Must Separate Communications and Ground (G) Cable from the Power 
(1[L1]) and Neutral (2[L2]) Cable at Least Two (2) Inches.
At Least Two (2) Inches
Display 
Button
Screen 
*
*
*
Reset
Indoor Unit Terminal
BR BL
RD
GR/YL