2. Specifications
Compact Model  _ 3
Indoor Units
* Model Name
A:Basic, C:Plasma
 Type
 Model                               Unit
                                                                       kW
 Cooling Capacity                                        kcal/h
                                                                     Btu/h
                                                                       kW
 Heating Capacity                                        kcal/h
                                                                     Btu/h
 Casing  
 
 
Body
                                 mm
 
Dimensions(WxHxD)
                                          inch
 
Front Panel
                      mm
                                                                      inch
 
Coil
 
Rows x Columns x FPI
 
                             Face Area                          m
2
                             Type 
 
Motor Output x Number 
W
                             Running Current                 A
 Fan  
Air Flow Rate(H / M / L)
      CMM
                                                                      cfm
                             Drive  
                             Motor type 
 Temperature Control  
 Sound Absorbing Thermal Insulation Material
 Safety Device  
 
 
Liquid Side                   mm(inch)
 
Pipe Connections
  Gas Side                      mm(inch)
 
Drain Pipe(Internal Dia.)
    mm(inch)
 Net Weight          Body                               kg(lbs)
                             Packaged                       kg(lbs)
 
Noise Level(Sound Press, 1.5m, H / M / L)
       dB(A)
 Power Supply                                           Ø, V, Hz
 Refrigerant Control  
 Transmission cable                                      mm
2
 Panel Color 
 Panel Name(Accessory)
4 Way Ceiling Cassette
ARNU15GTR*4  
4.5
3,900
15,400
5.0
4,300
17,100
Galvanized Steel Plate  
570 x 214 x 570  
22-7/16 x 8-7/16 x 22-7/16  
700 x 22 x 700  
27-9/16 x 7/8 x 27-9/16  
2 x 8 x 18  
0.21
Turbo Fan  
43 x 1  
0.2
9.2 / 7.5 / 7.0
325 / 265 / 247
Direct  
BLDC  
Microprocessor, Thermostat for cooling and heating  
Foamed polystrene  
Fuse  
Ø6.35(1/4)  
Ø12.7(1/2)  
25(1)  
13.7(30.2)
16.4(36.1)  
37 / 33 / 30
1, 220-240, 50  
1, 220, 60  
EEV  
CVV-SB 1.0~1.5 x 2C  
Morning fog  
PT-UQC  
Notes:
1. Capacities are based on the following conditions:
    Cooling   • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
                   • Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
                   • Interconnecting Piping Length 7.5m
                   • Level Difference of Zero
    Heating   • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
                   • Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
                   • Interconnecting Piping Length 7.5m
                   •  Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for
electrical work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
5. EEV: Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre. 
The values depends on the ambient conditions and values are normally higher in actual operation.
7. For the detail information of installation, please refer to the each installation section of standard model part.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60