2 _ Ceiling Cassette 4-way
Indoor Units
2. Specifications
* Model Name
A:Basic, C:Plasma
 Type
 Model                               Unit
                                                                       kW
 Cooling Capacity                                        kcal/h
                                                                     Btu/h
                                                                       kW
 Heating Capacity                                        kcal/h
                                                                     Btu/h
 Casing  
 
 
Body
                                 mm
 
Dimensions(WxHxD)
                                          inch
 
Front Panel
                      mm
                                                                      inch
 
Coil
 
Rows x Columns x FPI
 
                             Face Area                          m
2
                             Type 
 
Motor Output x Number 
W
                             Running Current                 A
 Fan  
Air Flow Rate(H / M / L)
      CMM
                                                                      cfm
                             Drive  
                             Motor type 
 Temperature Control  
 
 Sound Absorbing Thermal Insulation Material
 Safety Device  
 
 
Liquid Side                   mm(inch)
 
Pipe Connections
  Gas Side                      mm(inch)
 
Drain Pipe(Internal Dia.)
    mm(inch)
 Net Weight          Body                               kg(lbs)
                             Packaged                       kg(lbs)
 
Noise Level(Sound Press, 1.5m, H / M / L)
       dB(A)
 Power Supply                                           Ø, V, Hz
 Refrigerant Control  
 Transmission cable                                      mm
2
 Panel Color 
 Panel Name(Accessory)
4 Way Ceiling Cassette
       ARNU05GTR*4                 ARNU07GTR*4                ARNU09GTR*4
                 1.6                                     2.2                                     2.8
               1,400                                 1,900                                 2,400
               5,500                                 7,500                                 9,600
                 1.8                                     2.5                                     3.2
               1,500                                 2,200                                 2,800
               6,100                                 8,500                                10,900
  Galvanized Steel Plate      Galvanized Steel Plate     Galvanized Steel Plate
       570 x 214 x 570                 570 x 214 x 570                570 x 214 x 570 
   22-7/16 x 8-7/16 x 22-7/16         22-7/16 x 8-7/16 x 22-7/16        22-7/16 x 8-7/16 x 22-7/16 
        700 x 22 x 700                   700 x 22 x 700                  700 x 22 x 700 
    27-9/16 x 7/8 x 27-9/16           27-9/16 x 7/8 x 27-9/16          27-9/16 x 7/8 x 27-9/16 
            1 x 8 x 18                           1 x 8 x 18                          2 x 8 x 18
                0.21                                   0.21                                   0.21
            Turbo Fan                          Turbo Fan                         Turbo Fan
               43 x 1                                43 x 1                                43 x 1
                 0.2                                     0.2                                     0.2
         7.5 / 7.0 / 6.6                     7.5 / 7.0 / 6.6                     8.0 / 7.5 / 7.1
        265 / 247 / 212                  265 / 247 / 212                  283 / 265 / 251
               Direct                                 Direct                                Direct
               BLDC                                 BLDC                                BLDC
       Microprocessor,                 Microprocessor,                Microprocessor,
  Thermostat for cooling   Thermostat for cooling      Thermostat for cooling 
          and heating                       and heating                       and heating
     Foamed polystrene           Foamed polystrene           Foamed polystrene
                Fuse                                  Fuse                                  Fuse
           Ø6.35(1/4)                         Ø6.35(1/4)                        Ø6.35(1/4)
           Ø12.7(1/2)                         Ø12.7(1/2)                        Ø12.7(1/2)
                25(1)                                  25(1)                                 25(1)
            12.6(27.8)                          12.6(27.8)                         13.7(30.2)
            15.3(33.7)                          15.3(33.7)                         16.4(36.2)
           29 / 27 / 26                        29 / 27 / 26                        30 / 29 / 27
        1, 220-240, 50                   1, 220-240, 50                  1, 220-240, 50
            1, 220, 60                          1, 220, 60                          1, 220, 60
                EEV                                   EEV                                  EEV
  CVV-SB 1.0~1.5 x 2C       CVV-SB 1.0~1.5 x 2C       CVV-SB 1.0~1.5 x 2C
          Morning fog                       Morning fog                       Morning fog
PT-UQC
Notes:
1. Capacities are based on the following conditions:
    Cooling   • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
                   • Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
                   • Interconnecting Piping Length 7.5m
                   • Level Difference of Zero
    Heating   • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
                   • Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
                   • Interconnecting Piping Length 7.5m
                   •  Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics”
chapter should be considered for electrical work and design. Especially the power cable and circuit breaker
should be selected in accordance with that.
5. EEV: Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre. 
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60