1. Wait PCB(Inverter) DC voltage is discharged after main power off.
2. Pull out V, V, W COMP connector.
3. Set multi tester to resistance mode.
4. If the value between P and N terminal of IPM is short(0Ω) or open(hundreds MΩ), PCB(Inverter) needs to be
replaced.(IPM damaged)
5. Set the multi tester to diode mode.