240
INSTALLER SETTING
ENGLISH
Tank disinfection setting 1, 2
• Disinfection operation is special DHW tank operation mode to kill and to prevent growth of
legionella inside the tank.
- Disinfection active : Selecting enable or disable of disinfection operation.
- Start date : Determining the date when the disinfection mode is running.
- Start time : Determining the time when the disinfection mode is running.
- Max temp. : Target temperature of disinfection mode.
- Duration time : Duration of disinfection mode.
Time
Start time
Max temp
Duration time
Water temperature
(Inside DHW)
Temperature profile
of Disinfection operation
NOTE
DHW heating should be enable
• If Disinfection active is set as ’ Not use’, that is ‘disable disinfection mode’, Start date and
Start time is not used.
OK
OK

Table of Contents

Other manuals for LG THERMA V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG THERMA V and is the answer not in the manual?

LG THERMA V Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
RefrigerantR32
Operating Temperature Range (Heating)-25°C to 35°C
Power Supply220-240V, 50Hz
Dimensions (Indoor Unit)Varies by model
Dimensions (Outdoor Unit)Varies by model
Weight (Indoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model
Noise Level (Indoor Unit)20 - 45 dB(A)
Noise Level (Outdoor Unit)45 - 60 dB(A)

Related product manuals