TRAINING MANUAL WM3001H*A
WM3001H*A Page 85 Washer
At this connector on the main board, all
four wires are the neutral side of the line.
Voltage is applied to the solenoids by the
BLACK wire and the neutral side is
completed or broken to actuate each
solenoid.
YL Bleach
BL Hot
GY Prewash
BR Drain Pump
Color Code:
YL Yellow
BL Blue
GY Gray
BR Brown