Chapter 5 - Emergency operation
5.1 Overview
The steps for the emergency control, applicable systems and emergency controls during machine-operation are
specied in this chapter. The position, function and method of application of the emergency descent button or
emergency stop equipment are also introduced.
Notice: All personnel responsible for operation or who come into contact with the equipment must read this
complete manual (including this chapter) before using the machine this complete manual (including this
chapter) before using the machine at regular intervals.
Emergency stop switch
There are two red emergency stop switches on the machine, these are the big buttons. One button is located on the
control lever of the work panel, while the other is located on the ground control panel. As soon as the emergency stop
switches are pressed, the equipment stops immediately.
Warning
Check the equipment every day. Make sure that the emergency stop switches are correctly positioned and the
instructions and marking of the ground controls are afxed and clear.
Ground control position
The ground control panel is located on the side of the machine. With this panel, the platform control lever can be
operated and the working platform can be raised and lowered to the ground. Set the power selector switch to the
"ground" (ground) position and operate the lift/lower switch to perform the lift/lower operation.
Emergency lowering
The manual lowering valve can be used when power is completely lost. The work panel can be lowered under
gravity. The manual lowering lever is located on the right side of the machine, above the right front wheel. The lever
is connected to the manual lowering valve of the lifting hydraulic cylinder via a cable. The valve core can be opened
by pulling the lever for manual lowering of the work platform.
5.2 Emergency operation Application of ground control
Communication: understand how the ground control is used, in case of emergency.
The ground operator must be very familiar with the control features and functions of the ground control. The training
includes equipment operation. Read and understand the contents of this chapter and operate the control in case of
emergency.
Failure of machine operation by the operator
1) The equipment can only be controlled via a ground control with the help of other personnel and equipment
(crane, lifting equipment, etc.) where this control is necessary to eliminate risk or in case of emergency.
2) Other qualied operators on the control panel may use the control panel.
If the operation fails, do not proceed with this operation.
3) If the equipment operation fails or breaks during normal operation, the personnel must be taken to a safe
place and the equipment must be stabilised with a crane, fork-lift truck or other equipment.