EasyManua.ls Logo

Liebert InteleCool 2 User Manual

Liebert InteleCool 2
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Precision Cooling
For Business-Critical Continuity™
Liebert
®
InteleCool
®
2
User Manual - Outdoor Wall-Mount Air Conditioner, 2 - 5 Tons, 50 & 60 Hz

Table of Contents

Questions and Answers:

Liebert InteleCool 2 Specifications

General IconGeneral
BrandLiebert
ModelInteleCool 2
CategoryAir Conditioner
LanguageEnglish

Summary

1.0 Introduction

1.1 General

Details the system's design for convenience, dependability, and suitability for sensitive electronic equipment.

1.2 Standard Features

Lists key features like scroll compressor, refrigeration system, evaporator/condenser coils, blower, filter, cabinet, and controls.

1.3 Optional Features

Compressor Options

Covers compressor location, crankcase heater, and soft start features.

Cooling & Airflow Options

Includes high ambient condenser, economizer, and fresh air damper for cooling and airflow control.

Control & Appearance Options

Details lockout relay, common alarm, and panel color choices.

1.3.1 Refrigeration System Options

Low-Pressure Switch and Bypass Timer

Explains low-pressure switch function and optional bypass timer for low ambient conditions.

T-pack Control Packages

Details T-pack1 and T-pack2 options for telecom applications, including fan cycle control.

1.4 Ancillary Components

Ancillary Components

Covers wall thermostats, indoor grilles, and spare filters for system integration.

1.5 Accessories

Liebert Dual Unit Control

Describes a control for managing two units in a lead/lag fashion with various features.

2.0 INSTALLATION

2.1 Preparation

Covers room prep, location considerations, and equipment inspection before installation.

2.2 Unit Installation

Provides step-by-step instructions for mounting the unit to the wall, including safety precautions.

2.3 Piping Connections

2.4 Ducting

2.5 Electrical Connections

2.5.1 Power Connections

Covers wiring, grounding, voltage checks, and circuit breaker access for power supply.

2.5.2 Control Connections & Devices

Details low-voltage wiring for remote controls, thermostats, and dual unit controls.

2.6 Outside Air Damper—Optional

2.7 Economizer - Optional

3.0 CHECKLIST FOR COMPLETE INSTALLATION

4.0 STARTUP PROCEDURE

5.0 OPERATION

5.1 Compressorized Cooling

Explains the vapor-compression refrigeration cycle and how the unit cools air.

5.2 Economizer Cooling—Optional

Details how the economizer uses outside air for cooling when conditions are favorable.

5.3 Heating - Optional

Describes how units with optional heaters respond to heating calls.

5.4 Unit Controls

Remote Control & Standard Controls

Explains remote interface, high pressure switch, and refrigeration control options.

Optional Refrigeration Controls

Details low-pressure switch, bypass timer, T-pack1, and T-pack2 options for operating conditions.

Standard & Optional Timers/Alarms

Covers anti-short cycle timer, heater protection, lockout relay, and common alarm features.

6.0 MAINTENANCE

Routine Component Maintenance

Covers maintenance for filters, blower package, economizer, and heating components.

Refrigeration System Inspection

Emphasizes monthly inspection of refrigerant lines, discharge pressure, TEV, and condenser.

6.6 Compressor

6.6.1 Compressor Replacement

Outlines the procedure for replacing a compressor, including safety and recovery steps.

7.0 SPECIFICATIONS

7.1 Dimensional Data

Provides detailed dimensions of the unit and recommended clearances.

7.2 Technical Data

Presents technical specifications for various models and conditions, including capacity and airflow.

8.0 TROUBLESHOOTING

Troubleshooting Guide

Lists common problems, probable causes, and remedies for unit operation.

9.0 MAINTENANCE INSPECTION CHECKLIST

Related product manuals