EasyManua.ls Logo

Liebert UHA1R-0100 User Manual

Liebert UHA1R-0100
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Liebert
®
ITA 10kVA UPS
User Manual
Version
V1.2
Revision date
July 3, 2012
BOM
31012534
Emerson Network Power provides customers with technical support. Users may contact
the nearest Emerson local sales office or service center.
Copyright © 2011 by Emerson Network Power Co., Ltd.
All rights reserved. The contents in this document are subject to change without notice.
Emerson Network Power Co., Ltd.
Address: No.1 Kefa Rd., Science & Industry Park, Nanshan District 518057, Shenzhen
China
Homepage: www.emersonnetworkpower.com.cn
E-mail: support@emersonnetwork.com.cn

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Liebert UHA1R-0100 and is the answer not in the manual?

Liebert UHA1R-0100 Specifications

General IconGeneral
ModelUHA1R-0100
CategoryUPS
PhaseSingle-Phase
Frequency50/60 Hz
Weight130 kg (286.6 lbs)
Transfer Time0 ms
EfficiencyUp to 95%
Capacity1000VA
Battery TypeValve Regulated Lead Acid (VRLA)
Typical Backup Time5 min at full load, 14 min at half load
Communication InterfaceUSB, RS-232
Dimensions (H x W x D)4.3 x 9.8 x 15.7 inches
Input Voltage220/230/240V
Output Voltage220/230/240V

Summary

Safety Precautions

General Safety Warnings

Essential safety guidelines covering installation, usage, and handling of the UPS and its components.

Environmental and Battery Precautions

Important notes on operating environment, storage, and battery maintenance for optimal UPS life.

Chapter 1 Product Introduction

1.1 Features

Lists the key capabilities and design aspects of the Liebert ITA 10KVA UPS system.

1.6 Specifications

Provides detailed technical specifications for both standard and long back-up models of the UPS.

Chapter 2 Single UPS Installation And Commissioning

2.6 Single UPS Commissioning

Guides through the process of commissioning a single UPS unit after installation.

Chapter 3 Parallel UPS Installation And Commissioning

3.6 Commissioning Parallel System

Covers the steps for checking and commissioning the entire parallel UPS system.

Chapter 4 Display Panel

Chapter 5 UPS Operation Instructions

Chapter 7 Maintenance And Troubleshooting

7.2 Battery Maintenance

Details the procedures for maintaining the UPS battery, including safety precautions and charging.

7.6 Troubleshooting

Provides a table of common faults, their causes, and recommended disposal methods.

Appendix 1 Operation Guide For UPS Parallel Power Distribution

Related product manuals